Ausstattung – Equipment
KGV - Single-Stage Radial Compressor
- Investigating possibilities for anomaly detection and condition-based maintenance using vibration and acoustic measurement data
- maximum pressure ratio: 2,2
- maximum mass-flow rate: 2 kg/s
- maximum specific head: 70 kJ/kg
- Rotor speeds up to 22000 rpm
- IGV positions: -20° to +70°
Measurement Equipment
- Accelerometers with frequency range up to 20 kHz
- Acoustic free field microphones with frequency range up to 20 kHz
- Measuerments of process data: inlet/outlet Temperature, inlet/outlet Pressure, Shaft Vibration, Rotor Speed, Bearing and Oil temperature
Universal data acquisition system:
- HBM QuantumX 410B (≤ 100 kS/s, 12-channels)
- HBM QuantumX 840B (≤ 50 kS/s, 8-channels)
Single-Stage Radial Compressor
- single-stage radial compressor
- investigating the impact of wet compression on the compressor map
- nominal pressure ratio: 2
- nominal mass flow rate: 2,5 kg/s
- nominal power required: 440 kW
- adjustable air temperature at compressor inlet 20-90 °C
- water injection via pneumatic atomizing nozzles
Measurement Equipment
- probe calibrator:
- modified and automated TSI 1127 (Ma ≤ 0.95)
- modified and automated TSI 1127 (Ma ≤ 0.95)
Stator Components
- rapid manufacturing / selective laser sintering (SLS)
- stator geometries for different flow coefficients (≤ 𝝋 = 0.12)
- low cost and time efficient testing
- Mach numbers up to Ma ≤ 0.8 at diffusor inlet
- Reynolds numbers up to Re ≈ 5.5∙10⁵
- separate generation of steady and unsteady inlet flow characteristics
- five hole probes with thermocouple
- steady state and time-resolved wall-bounded pressure measurements
- hot wire probes for measuring turbulent statistics (< 200 kHz)
Measurement Equipment
Hot Wire Anemometry
- measurement systems:
- Dantec Dynamics – StreamlinePro
- TSI – IFA 300
- data acquisition system:
- HBM QuantumX 410B (≤ 200 kS/s)
- probe calibrator:
- modified and automated TSI 1127 (Ma ≤ 0.95)
- modified and automated TSI 1127 (Ma ≤ 0.95)
Probe Traversing Device
- translational and rotational motion
- variable translation travel
- step control with micro switches
- step resolution
- minimal translation step size: 5 µm
- minimal rotational step size: 0.07 °
- electrical isolation through FDM* manufactured clamping fixture
Rotating Cavity
Rotating disk in cylindrical cavity for aerodynamics and acoustics measurements
- different working fluids, pre-mix vessel
- different disks with different shapes and surface roughness
- non-dimensional axial gap width down to G = 0.0125
- circumferential Reynolds numbers up to Re =1.2∙10⁸ (CO2)
- circumferential Mach numbers up to Ma = 0.75 (CO2)
Investigation of acoustic modes and disk vibration as means of studying rotor-stator interaction in a simplified radial compressor model
- two loudspeakers as excitation source capable to excite acoustic and structural modes of the gas and disk, respectively
Measurement Equipment
- pressure and temperature sensors in front and back cavity
- strain gauges and pressure sensors on disk
- rotatable pressure sensor (for mode identification)
- hot wire anemometry
Dry Gas Seals
- design operating condition: 18,000 rpm, 100 bar
- overhung configuration with rigid couplings
- reduced turnaround time
- direct access to test seals and sensors
- film thickness (0 – 50 µm) and static pressure (≤ 110 bar) measurements in the running gap
Measurement Equipment
- high frequency pressure measurements with ultraminiature pressure probes (≤ 100 kHz)
- proximity sensors for measuring the film thickness and the displacement of the parts
- fast response surface thermocouples for the ring temperature
EMMA
Experimental Multi-phase Measurement Application
- maximum steam massflow = 55 kg/h
- connection for external steam generator for possible steam massflow increase
- maximum absolute steam pressure = 5 bar
- maximum superheated steam temperature = 300 °C
- cooling capacity of 10kW for wallsubcooling to induce condensation
- 8-zone controllable heating system for wallsuperheating to induce evaporation
- preheated liquid water injection for wet steam generation
- modular measurement section for variation of wall geometries
- optical access to the measurement section
- resolvable liquid film thickness range = 1 µm – 3000 µm
Measurement Equipment
- heat transfer coefficient (HTC) measurement systems for condensation and evaporation
- infrared-interferometric filmthickness measurement system
- chromatic-confocal filmthickness measurement system
- extinction measurement system for determination of wet steam density
eco.MAC
evaporative cooling Multiphase Axial Compressor
- Four-stage axial compressor
- investigation of wet compression and interstage injection
- pressure ratio: 1.9
- mass flow: 15 kg/s
- power at shaft: 980 kW (Driven by two DC-engines and tandem gear box)
- injection of highly pressurized water (up to 200 bar)
- in front of the compressor
- behind stator 1 (SLM manufactured stator, containing internal conduits to supply twin jet nozzles with water)
- adjustable IGV and stator blades
- droplet measurements via nonintrusive LDA/PDPA-system
To get an insight into the compressor, watch our VR video.
Measurement Equipment
- torque and rotational speed at shaft
- inlet mass flow rate
- steady state pressures in front/behind every stage
- thermocouples in front/behind every stage
- bearing oscillations (proximity sensors)
- five hole probe with thermocouple in between stator and rotor
- non-intrusive PDPA (Phase doppler particle analysis)
spray characterization in superposed flows via light scattering mechanism
measurement of droplet diameters and velocities- Argon-Ionen-Laser
- transceiver-probe: TSI-TR260 (2D-LDA)
- wavelenghts: 488 nm and 514.4 nm
- focal lenghts: 512, 350 mm
- receiver-probe: TSI-RV2100 Receiver (2D-PDPA)
- focal length: 500 mm
- backward and front scattering (e.g. off-angle: 150, 30 degree)
- traversing in x,y,z,φ-coordinates
STEVE - Steam turbine control valve I
Steam Turbine Experimental Valve Enhancement
- investigation of fluid-structure-interaction in a single control valve
- modular design
- interchangeable diffusor-geometry
- complete interchangeable inner geometry
- mach similarity to full scale ensured
- pressure ratios
- first test rig with full vibrational similarity due to
- material selection
- operating conditions
Measurement Equipment
- highly dynamic universal data acquisition system:
- HBM QuantumX 410B (≤ 200 kS/s), 20-channels
- high frequency displacement measurements with Eddy current proximity sensors (≤ 125 kHz)
- high frequency pressure measurements with ultra-miniature pressure sensors (17 bar, nat. frequency 550 kHz)
- high frequency piezo electric force measurements (1 kN, 10 kHz)
GÖRLI - Steam turbine control valve II
cooperation with Siemens location in Görlitz
- investigating of fluid-structure-interaction
- investigating interaction between two control valves
- modular design
- interchangeable diffusor-geometry
- complete interchangeable inner geometry
- mach similarity to full scale ensured
- full vibrational similarity due to
- material selection
- operating conditions
Measurement equipment
- highly dynamic universal data acquisition system:
- HBM QuantumX 410B (≤ 200 kS/s, 20-channels)
- HBM QuantumX 840B (≤ 40 kS/s, 8-channels)
- high frequency strain measurements on valve plug with miniature strain gauges
- high frequency pressure measurements with ultra-miniature pressure sensors (17 bar, nat. frequency 550 kHz)
- high frequency piezo electric force measurements (1 kN, 10 kHz)
- high frequency displacement measurements with Laser proximity sensors (110-190 mm, 392 kHz)
High Pressure Wind Tunnel with Pre-Heating
- experimental investigation of water injection for compressor applications
- interstage injection in a vaned cascade with curved flow path (shown here)
- cylindrical nozzles in a straight glass pipe
- data
- superimposed air flow:
- Maair ≤ 0.6
- Tmax = 450 °C
- pmax = 10 bar @ 1.5 kg/s
- ṁmax = 2 kg/s @ 2 bar
- injected water
- Tmax = 200 °C
- pmax = 250 bar @ 1.35 kg/s
- superimposed air flow:
Measurement Equipment
non-intrusive PDPA (Phase doppler particle analysis)
spray characterization in superposed flows via light scattering mechanism
measurement of droplet diameters and velocities
- Argon-Ionen-Laser
- transceiver-probe: TSI-TR260 (2D-LDA)
- wavelenghts: 488 nm and 514.4 nm
- focal lenghts: 512, 350 mm
- receiver-probe: TSI-RV2100 Receiver (2D-PDPA)
- focal length: 500 mm
- backward and front scattering (e.g. off-angle: 150, 30 degree)
- traversing in x,y,z,φ-coordinates